Mini-Split Sizing Calculator

Right-size a ductless mini-split head — the BTU a room needs and the nearest standard head to buy.

Inputs
sq ft
Results update as you type — no submit
ResultsLIVE
Required cooling
10,000 BTU/hr
≈ 2.93 kW
Suggested head12,000 BTU/hr · 3.52 kW
Rule-of-thumb estimate — a Manual J load calculation by a licensed HVAC professional is definitive before you buy equipment.
Formula
load = 400 × 25 BTU/ft² = 10,000 BTU/hr → 12,000 BTU head

A ductless mini-split serves one zone, so sizing a head starts with the same area rule the whole industry uses: roughly `20` BTU/hr per square foot of floor in a mild climate, rising toward `25` in a moderate one and `30` where the head also carries a cold heating season. Multiply your room area by that factor to get the cooling load the head must cover.

Manufacturers stock heads in fixed capacities — `6,000`, `9,000`, `12,000`, `15,000`, `18,000`, `24,000`, `30,000`, and `36,000` BTU/hr — so the calculator rounds your load up to the smallest head that meets it. A `400` square-foot room in a moderate climate needs about `10,000` BTU/hr, which a `12,000` BTU head covers comfortably.

Bigger is not better with mini-splits. An oversized head short-cycles: it blasts to temperature, shuts off, and never runs long enough to wring humidity out of the air, leaving the room cold and clammy. Modern inverter heads modulate well, but you still want the smallest head that carries the load. For a whole house, or a room with heavy sun or cathedral ceilings, a Manual J load calculation is the definitive sizing before you buy.

Worked example
Room `400` sq ft · moderate climate (`25` BTU/ft²)
load = 400 × 25 = `10,000 BTU/hr` (`2.93 kW`)
nearest head ≥ load = `12,000 BTU/hr` head
Take the room's square footage and multiply by 2030 BTU/hr per square foot depending on climate, then round up to a standard head. A 250 sq ft bedroom needs about 5,0007,500 BTU/hr, so a 6,000 or 9,000 BTU head fits. Our calculator picks the nearest head for you.
SOURCESENERGY STAR / ACCA room-sizing rule-of-thumb · manufacturer ductless head catalogs
Rule-of-thumb estimate — a Manual J load calculation by a licensed HVAC pro is definitive